Yayınlanmış 1 Ocak 2018 | Sürüm v1

Unbiased Charged Circular CMUT Microphone: Lumped-Element Modeling and Performance

  • 1. Bilkent Univ, Elect & Elect Engn Dept, TR-06800 Ankara, Turkey
  • 2. Bilkent Univ, Acoust & Underwater Technol Res Ctr, TR-06800 Ankara, Turkey
  • 3. Univ Texas Austin, Dept Mech Engn, Austin, TX 78712 USA

Açıklama

An energy-consistent lumped-element equivalent circuit model for charged circular capacitive micromachined ultrasonic transducer (CMUT) cell is derived and presented. It is analytically shown and experimentally verified that a series dc voltage source at the electrical terminals is sufficient to model the charging in CMUT. A model-based method for determining this potential from impedance measurements at low bias voltages is presented. The model is validated experimentally using an airborne CMUT, which resonates at 103 kHz. Impedance measurements, reception measurements at resonance and off-resonance, and the transient response of the CMUT are compared with the model predictions.

Dosyalar

bib-d6362abc-e72b-4a18-80c0-81cf81b93791.txt

Dosyalar (252 Bytes)

Ad Boyut Hepisini indir
md5:6082bc63cb6a73221c4f2258f024b426
252 Bytes Ön İzleme İndir