Membrane fouling in thermophilic membrane bioreactor with different sludge retention times
Yazarlar/Oluşturanlar
- 1. Gebze Tech Univ, Dept Environm Engn, Kocaeli, Turkey
- 2. Bulent Ecevit Univ, Dept Environm Engn, Zonguldak, Turkey
Açıklama
As membrane fouling is based on various factors, it is a complex phenomenon that is hard to estimate. This study investigated membrane fouling in a thermophilic jet loop membrane bioreactor (JLMBR). With this purpose, four different empirical membrane fouling models with different sludge retention times were applied on the flow data obtained in the system. As a result of the model implementation, it was found for all sludge retention times that, standard blocking is effective in the first 1.5 hours of filtration, while cake filtration was dominant in the remaining duration. Additionally, it was observed that as the sludge retention time increases, membrane fouling rate decreases.